The nitrogen purging system 1000 advantage efficiently utilises dry nitrogen to protect electronics, optical and high-voltage laser systems, and equipment requiring gas drying and oxygen inhibition. This system connects the dry gas source and the equipment port via an inlet connection.

Accurate Pressure Leak Detection

The inert gas purging system allows users to configure settings, display dewpoint measurements and process control values in Degrees Celsius or Fahrenheit, with pressure units in Kpa or psi. The nitrogen inerting system has liquid displays to relay information during an operation.

The dewpoint monitor displays the dryness of the gas before purging and enables users to assess moisture levels within the equipment, facilitating a seamless purging procedure. Additionally, the remote dewpoint sensor monitors progress and automatically shuts off the dry gas supply upon reaching the optimal dewpoint.

Global Voltage and Frequency Compatibility

The system is designed with four testing capabilities to verify equipment sealing standards. With a pressure leak rate display precision of 0.01 psi, the system allows for precise pressure testing within a range of 10.3 Kpa (1.5 psi) to 34.4 Kpa (5.0 psi).

The gas blanketing system suits diverse applications, including optical instruments, storage containers, underwater equipment, surveillance apparatus, laser systems, and SF6 switchgear. The high-voltage equipment purge system operates seamlessly across global voltages and frequencies (100 to 230 VAC at 50-60 Hz).

  • Uses dry nitrogen to purge optical, electronic, and high-voltage laser systems, ensuring gas drying and oxygen inhibition
  • Easy configuration withd display dewpoint measurements, process control values and pressure units
  • Verify equipment sealing standards with precision (0.01 psi) pressure leak rate display
  • Pressure testing range: 10.3 Kpa to 34.4 Kpa
  • Ensures gas dryness and aiding quality control with a Dewpointstat feature to enhance purging
  • Remote Dewpoint sensor to monitor progress and automatically shut-off gas supply at a specified dewpoint
  • Works with global voltages (100-230 VAC at 50-60 Hz)
  • Suitable for optical instruments, storage, underwater gear, surveillance, lasers, and SF6 switchgear
Useable Gases Air, Nitrogen, SF6, Helium, Argon
Selectable Pressure Ranges 10.3 Kpa (1.5 psi)
17.2 Kpa (2.5 psi)
34.4 Kpa (5.0 psi)
Display Range Pressure 0 to 34.4 Kpa (0-5.0 psi)
Display Range Dewpoint (Selectable)
+20ºC to –80ºC dewpoint
+68ºF to –94ºF dewpoint
Resolution
0.1ºC dewpoint
Accuracy
+/- 2ºC dewpoint
Data Output Pressure 0 – 5 Volts
Data Output Dewpoint 0 – 5 Volts
Power
100-230 volt 50 hz – 60 hz
Power Consumption
3 amps
Dimensions
490W x 425D x 190H (closed)
Weight
12 kilograms
Ingress Protection
IP54 (Closed Case)
Operating Temp
-10ºC to +50ºC
Storage Temp
-50ºC to + 65ºC
Proof Pressure
input 137 Kpa (20 PSI)
Flowrate (typical)
20 litres per minute

Nitrogen Enhanced Purging System 1000 Advantage Product Brochure: Download